Supplier of HPLC Sample Vials Since 2007.
Main
Products
1.5 ML/2ML 8-425 Screw Neck Autosampler Vials ND8

1.5 ML/2ML 8-425 Screw Neck Autosampler Vials ND8

Details Products name 1.5 ML/2ML 8-425 Screw Neck Autosampler Vials ND8 Dimension 8mm Cap Color White and Black Septa details White,Red,Blue,1.5mm thickness. Material PP for Cap, PTFE/Silicone for Septa Package 100pcs/Pack Cap type Close top, Open top Septa type Non-slit, Pre-slit Description 1.5 ml vials from Aijiren Technology, Inc with high quality and favorable price. Zhejiang Aijiren is a manufacturer of Laboratory consumables. We supply autosampler vials, septa and c...
More
1.5ml 9mm Short Thread Autosampler Vials ND9

1.5ml 9mm Short Thread Autosampler Vials ND9

Details Products name 1.5mL 9mm Short Thread Autosampler Vial ND9 Dimension 9mm Cap Color Blue, Black, Red, Yellow Septa details White,Red,Blue,1mm thickness. Material PP for Cap, PTFE/Silicone for Septa Package 100pcs/Pack Cap type Close top, Open top Septa type Non-slit, Pre-slit Description 1.5 ml vials from Aijiren Technology, Inc with high quality and favorable price. Zhejiang Aijiren is a manufacturer of Laboratory consumables. We supply autosampler vials, septa and ...
More
1.5ml 10-425 Screw Autosampler Vials ND10

1.5ml 10-425 Screw Autosampler Vials ND10

Details Products name 1.5ml 10-425 Screw Autosampler Vials ND10 Dimension 10mm Cap Color Black Septa details White,Red,1.5mm thickness. Material PP for Cap, PTFE/Silicone for Septa Package 100pcs/Pack Cap type Open top Septa type Non-slit Description 1.5 ml vials from Aijiren Technology, Inc with high quality and favorable price. Zhejiang Aijiren is a manufacturer of Laboratory consumables. We supply autosampler vials, septa and caps at factory price. 1.  1.5ml 10-425 Scre...
More
1.5mL 11mm Crimp Ring Autosampler Vial ND11

1.5mL 11mm Crimp Ring Autosampler Vial ND11

Details Products name 1.5mL 11mm Crimp Ring Autosampler Vial ND11 Dimension 11mm Cap Color Silver Septa details White, Red,1mm thickness. Material Aluminum for Cap, PTFE/Silicone for Septa Package 100pcs/Pack Cap type Open top Septa type Non-slit, Pre-slit Description 1.5 ml vials from Aijiren Technology, Inc with high quality and favorable price. Zhejiang Aijiren is a manufacturer of Laboratory consumables. We supply autosampler vials, septa and caps at factory price. 1. ...
More
1.5mL 11mm Snap Ring Autosampler Vial ND11

1.5mL 11mm Snap Ring Autosampler Vial ND11

Details Products name 1.5mL 11mm Snap Ring Autosampler Vial ND11 Dimension 11mm Cap Color Natural, Blue, Red Septa details White, Red, Blue,1mm thickness. Material PE for Cap, PTFE/Silicone for Septa Package 100pcs/Pack Cap type Open top Septa type Non-slit, Pre-slit Description 1.5 ml vials from Aijiren Technology, Inc with high quality and favorable price. Zhejiang Aijiren is a manufacturer of Laboratory consumables. We supply autosampler vials, septa and caps at factory...
More
4mL 13-425 Screw Neck Autosampler Vial ND13

4mL 13-425 Screw Neck Autosampler Vial ND13

Details Products name 4mL 13-425 Screw Neck Autosampler Vial ND13 Dimension 13mm Cap Color Black Septa details White, Red, Nature 1.5mm thickness. Material PP for Cap, PTFE/Silicone for Septa Package 100pcs/Pack Cap type Close top, open top Septa type Non-slit Description 4 ml vials from Aijiren Technology, Inc with high quality and favorable price. Zhejiang Aijiren is a manufacturer of Laboratory consumables. We supply autosampler vials, septa and caps at factory price. 1...
More
16mm Test Tubes for Water Analysis

16mm Test Tubes for Water Analysis

Details Products name 16mm Test Tubes for Water Analysis Dimension 16mm Cap Color White Material PC for Cap, PTFE/Silicone for Septa Package 100pcs/Pack or 25pcs/Pack Cap type Close top Septa type Non-slit Description COD vials from Aijiren Technology, Inc with high quality and favorable price. Zhejiang Aijiren is a manufacturer of Laboratory consumables. We supply autosampler vials, Headspace vials and COD vials at factory price. 1. PTFE Septa for 16mm test tube Closures, W...
More
20-60mL 24-400 Screw Neck Storage Vial ND24

20-60mL 24-400 Screw Neck Storage Vial ND24

Details Products name 20-60mL 24-400 Screw Neck Storage Vial ND24 Dimension 24mm Cap Color Black, White Septa details Nature,3mm thickness. Material PP for Cap, PTFE/Silicone for Septa Package 100pcs/Pack Cap type Open top, Close top Septa type Non-slit Description Sample Storage vials from Aijiren Technology, Inc with high quality and favorable price. Zhejiang Aijiren is a manufacturer of Laboratory consumables. We supply Sample Storage vials, septa and caps at factory pr...
More
HPLC Sample Vials Supplier
ABOUT
ZHEJIANG AIJIREN,INC.
Zhejiang Aijiren Technology, Inc. is a global supplier of life-science, chemistry, laboratory consumables, etc. Our major products are high performance liquid chromatography & gas chromatography consumables such as Chromatography Autosampler Vials with closures, inserts, crimper and syringe filters, etc; Water analysis consumables such as COD test tube.
100+
Current Employee
15
YEARS Production experience
300,000
square meters Area
200+
Processing Equipment
Company Profile
Factory View
Factory View
why choose us
Customers for HPLC Sample Vials
Case
Show
The Australian Customer’s V947 Autosampler Vial Order is Completed
The Australian Customer’s V947 Autosampler Vial Order is Completed
A customer from Australia talked to Aijiren’s sales manager Maggie about which Vias they needed. He said that he needed a 2ml Autosampler Vial, and Maggie asked about Screw top vial, Snap top vial or Crimp top vial. The customer asked about the differences between these three types of Vias. Maggie explained the difference between the three types of Vials and recommended Screw top Vial, stating that this type of Vials is the best-selling product, and it can also match most Autosamplers ...
American Customer Ordered 100,000 Boxes of 9-425 2ml HPLC Vials
American Customer Ordered 100,000 Boxes of 9-425 2ml HPLC Vials
A customer contacted Aijiren through Alibaba and communicated with our sales manager Joshua. After learning about Aijiren’s situation and strength, he proposed to buy our 9-425 HPLC Vials, and they needed a lot of quantity. We first decided to send some samples to the customer. He asked for a 2ml 9mm hplc vial with graduated borosilicate glass. Therefore, we sent a few packs of 9mm short-thread sample vials V927 produced by Aijiren as samples for customers to test. Aijiren 2ml 9mm cle...
5000-boxes-of-blue-screw-cap-10-425-hplc-vial-sent-to-singapore
5000-boxes-of-blue-screw-cap-10-425-hplc-vial-sent-to-singapore
A customer from Singapore wanted to purchase 2ml 10mm HPLC Vial. He searched for Aijiren on the Internet and contacted our account manager. Aijiren sent samples last month. After the trial, the customer placed an order for 5000 from Aijiren. Box of Blue Screw Cap 10-425 Vial. Aijiren has been working hard to produce 10-425 Vials after receiving the order, using a new and efficient production machine in the factory, and several workshops are operating at the same time, producing and packaging...
Read more Cases
+
ALL CASE
Latest
news
Only three USP chapters reach the vial, and only one of them names it
Only three USP chapters reach the vial, and only one of them names it
10 月 25, 26

Only three USP chapters reach the vial, and only one of them names it

A 200-injection validation run on a 2 mL HPLC method came back with a %RSD of 3.8% on the early-eluting peak. The method had passed system suitability at 0.9% two weeks earlier. Nothing on the instrument had changed. What had changed was the vial lot: same catalog number, same supplier, new manufacturing batch, and the septa were fitted with a 0.008 in thinner PTFE facing. That is the shape of most USP compliance problems with OEM vials. The compendium does not tell you which septum to buy....
How a needle actually removes material from a closure
How a needle actually removes material from a closure
10 月 25, 26

How a needle actually removes material from a closure

A 96-position autosampler run on a / tower aborted at injection 41 with a syringe error, and the septum on that vial had a clean 0.48 mm disc punched out of its center. The instrument had been running the same lot of oem vial closures for three weeks. Nothing about the chromatograms looked wrong before the abort, which is the part that matters: coring debris and needle damage are mechanical failures that show up in the syringe and the guide long before they show up in the data. This...
The dimensional interface: what actually has to match
The dimensional interface: what actually has to match
10 月 22, 26

The dimensional interface: what actually has to match

I once watched a lab reject three full cases of 9 mm wide-mouth vials because the crimper wouldn’t seat the seals squarely. The vials were dimensionally fine on paper. The problem was that the lab had switched autosamplers six months earlier and never re-checked the neck geometry against the new gripper. That single mismatch cost about $4,000 in vials, a week of instrument downtime, and a re-run of 96 samples. Matching an OEM vial to your autosampler or inlet is not a catalog exercise...
Contact
Chat
Email
Whatsapp
Top